1. Setting operation (e.g., start-up
temperature 2˚C, shutdown temperature 8˚C)
(1) Set the shutdown temperature:
In the normal interface, press the “SET” button
for more than 3 seconds until ‘st’ is displayed. Then press the
‘‘SET’’ button again. At this point, you can use the
▲▼
keys to adjust the shutdown temperature value to 2.0°C. The
shutdown temperature value range is between C4 and C5.
(2) Set startup temperature:
Startup temperature = shutdown temperature +
cooling hysteresis
In the normal interface, press and hold the “SET”
button for more than 3 seconds until “st” is displayed. Then
press the
▲
button again. The display will show “Po”. Press the “SET”
button, and the display will show “0”. Use the
▲▼
buttons to adjust the display to 55, then press the “SET”
button. The display will show “C1.” Press the “SET” button to
enter the parameter settings, then use the
▲▼
buttons to adjust to 6.0˚C.
Note: Shutdown temperature = Set value;
Startup temperature = Set value + C1 value.
2. System Menu Settings
(1) In normal operating conditions, press and
hold the “SET” button for more than 3 seconds until the
temperature display window shows the parameter code “St,”
indicating entry into the system settings menu. Use the
▲
or ▼
key to switch the parameter code item to Po, press “SET” to
display 0, then use the
▲
or ▼
key to adjust the value to “55”, and then click “SET” to enter
the administrator menu, where you can adjust the basic
parameters C1 to F6.
(2) In the system menu settings state,
pressing the “RST” key or remaining without any key presses for
30 seconds will save the modified parameter values and exit the
system menu settings state. If an error occurs during parameter
saving, the temperature display window will show “Err”, and
after 5 seconds, it will return to the normal display state. |